Product Features:

1. Meet UL, CE requirements.
2. Ultra-thin, ultra-small.
2. Input voltage (90 ~ 264Vac)
3. Low ripple and low noise.
4. Output overload and short circuit protection
5. High efficiency, high power density.
6. Products designed to meet the requirements of EMC and safety testing.
7. Low power consumption, environmental protection, no-load loss <0.1W.
8.100% load aging and testing

Environmental conditions:

Operating temperature:-20- + 60
Storage temperature-40- + 80
Relative humidity5-95%
CoolingNatural cooling
Atmospheric pressure80-106Kpa
Altitude2000m
VibrationVibration factor 10 ~ 500Hz, 2G10min. / 1cycle, 60min.each along X, Y, Z axes

Electrical Characteristics:

Rated input voltage100-240VAc
Input voltage range90-264VAc
Maximum input current0.2A
Input inrush current 10A
The maximum input voltage270VAc
Enter slow start50mS
Input Low Voltage EfficiencyVin = 110VAc, full load 69%
Input High Voltage EfficiencyVin = 220VAc, full load 70%
Long-term reliabilityMTBF100,000h
Load rated output voltage+ 5 ± 0.1VDc
Full rated output voltage+ 5 ± 0.2VDc
Maximum output current short1000mA
The maximum output current for a long time600mA
Voltage Regulation± 0.2%
Load Regulation± 0.5%
Output ripple and noise(MVp-p)50mV
Rated input voltage, output at full load. With 20MHz of bandwidth,Load side and 10uF and 0.1uF capacitor to be tested.
Switch Overshoot(Rated input voltage, output 10% load) 5% VO
Output overcurrent protection150-200% of the output maximum load.
Output short circuit protection: Direct short circuit the normal output, automatically resume normal operation after a short circuit removal.

Safety features:

Product designed to meet UL, CE safety certification requirements.

Security 4.2 is compatible with the electromagnetic

Designed with the input of 0.5A UL certification of insurance;
PCB board using double-sided copper-clad plate production, materials for the 94-V0 fire rating level;
Safety standards in line with UL1012, EN60950, UL60950
Insulation voltage I / P-O / P: 2500VAC
Insulation resistance I / PO / P> 100M Ohms / 500VDC 25 70% RH
Conduction and radiation comply with EN55011, EN55022 (CISPR22)

Electrostatic discharge IEC / EN 61000-4-2 level 4 8kV / 15kV
RF radiation immunity IEC / EN 61000-4-3 See Application Note

Design temperature Safety

At room temperature, the inner surface temperature of the power supply capacitor, the main transformer and so a maximum 90 ;
Maximum housing surface temperature does not exceed 60 ;